1 / 2
Also called: condensate trap, TD trap, thermodynamic steam trap, float steam trap, bucket trap
- Since 2019
- GST registered
- MSME (Udyam) registered
- ISO 9001:2015 certified
Delivery across Mumbai, Thane and Navi Mumbai; supply all over India.
What it is
A steam trap lets condensate and air out of a steam line or steam-heated equipment while holding the live steam in. Without traps, condensate collects in pipes and heat exchangers, cutting heat transfer and causing water hammer, and steam is wasted through open drains.
Each type of trap suits different duties. To choose one we need the steam pressure, the condensate load, where it drains (steam main, process equipment or tracer line) and the connection size and type.
Types
The common types. Tell us the one your job needs.
Type
- Thermodynamic (TD)A disc opens for condensate and snaps shut when flash steam reaches it. Small and robust; for steam main drains and tracing.
- Ball floatA float opens the valve as condensate rises, and a thermostatic element vents air. Drains continuously; the first choice for heat exchangers and process equipment.
- Inverted bucketA bucket sinks to open on condensate and floats up to close on steam. Tough; for mains drains and higher pressures.
- Balanced pressure (thermostatic)A capsule opens on cooler condensate and air. Good for venting air at start-up and for light loads.
- Bimetallic (thermostatic)Bimetal elements close as the temperature rises. Tolerates water hammer and superheat.
Ends
- ScrewedBSP or NPT threads, the usual end in small sizes.
- Socket weldWelded into small-bore steel lines.
- FlangedLarger traps and plants that prefer flanged joints.
Options
- Built-in strainerKeeps scale and dirt off the trap seat.
- Test valve or sight glassShows whether the trap is working.
- Trap stationTrap with isolating valves, strainer and check valve, ready to fit.
Grades and standards
Standards buyers commonly specify. Quote the one in your specification.
- ISO 6552
- Automatic steam traps: definition of technical terms.
- ISO 6948
- Automatic steam traps: production and performance tests.
- ISO 7841
- Automatic steam traps: determination of steam loss.
- ISO 7842
- Automatic steam traps: determination of discharge capacity.
- ISO 6554
- Flanged steam traps: face-to-face dimensions.
- IBR
- Traps on steam lines under the Indian Boiler Regulations need IBR documents.
Where it is used
Services
- Steam main drains
- Heat exchangers and coils
- Jacketed vessels and dryers
- Steam tracing
- Unit heaters
Industries
- Boiler houses
- Textile processing
- Food and dairy
- Pharmaceutical and chemical plants
- Rubber and tyre plants
- Hotels and hospitals
Documents with the order
- Maker's test certificate supplied where available. Ask when you order, and say if IBR documents are needed.
Common questions
Which trap should I use to drain a steam main?
A thermodynamic or inverted bucket trap is the usual choice, fitted at the bottom of a drain pocket at low points and at regular intervals along the main.
Which trap suits a heat exchanger?
A ball float trap, because it drains condensate as fast as it forms, even when the steam pressure in the exchanger changes with the load.
Why fit a strainer before a steam trap?
Scale and dirt stop the trap closing tightly, so it wastes steam. Many traps have a built-in strainer; otherwise fit a Y-strainer before the trap.
How can I tell if a trap is passing steam?
A trap that blows steam all the time is leaking, and a cold trap is blocked. Test valves, sight glasses, temperature checks and ultrasonic testers help check traps during routine surveys.
Do you supply IBR steam traps?
Tell us in your enquiry if the trap is for a line under the Indian Boiler Regulations, so we quote traps supplied with IBR documents.
Do you supply outside Mumbai?
Yes. We deliver across Mumbai, Thane and Navi Mumbai, and supply all over India.
More line accessories valves
Used with
Valves · RegulatingGlobe ValveThrottles and regulates flow in steam, water and process lines.
Valves · RegulatingPressure Reducing ValveBrings line pressure down to a set, steady value.
Valves · SafetySafety Relief ValveProtects boilers, vessels and lines from over-pressure.
Pipes · SeamlessMS Seamless PipePipe with no weld seam for high pressure, steam, boiler and oil lines.
Valves · Non-returnForged Check ValveStops backflow in small, high-pressure lines.
Get an accurate quote, faster
Send these details with your enquiry, or simply send your BOQ. Add the fittings and valves you need to the same list.
Or email your list to admin@sktradingandco.in
For valves, tell us- Steam pressure
- Condensate load (kg/h)
- Application (mains drain, process or tracer)
- Connection size
- End connection
- IBR needed (yes or no)
- Quantity